A complete declaration analysis for thermal treatment must identify all relevant contaminants in the source material, include fundamental physicochemical parameters, and have been prepared in accordance with recognized standards. It forms the basis for determining whether a waste material may be treated in a thermal desorption plant and under what conditions acceptance takes place. The following sections answer the most important questions regarding the content, requirements, and special considerations of a compliant declaration analysis.
Which contaminants must be mandatorily identified in the declaration analysis?
The declaration analysis for thermal treatment must identify all contaminants that are expected to be present in the waste based on experience or the origin of the material. These typically include mineral oil hydrocarbons (MKW), BTEX, PAHs, phenols, PCBs, PFAS/PFOS, cyanides, nitroaromatics, PCDD/PCDF, and chlorinated hydrocarbon compounds. If mercury contamination is suspected, Hg must also be determined.
Which specific contaminant groups must be analyzed depends on the site’s history of use. At a former gasworks, PAHs and BTEX are standard. At an industrial site with chemical production, chlorinated solvents or specific organics may be added. The contaminant analysis must reflect the actual contamination profile of the soil or waste, not merely work through a standard program.
Important: If contaminants are not analyzed despite being expected based on prior use, this can lead to rejection of the delivery or problems during plant operation. A complete disposal analysis protects all parties involved and is a prerequisite for proper treatment.
Which fundamental physicochemical parameters belong in a declaration analysis?
In addition to contaminant analysis, fundamental physicochemical parameters are an indispensable component of every declaration analysis for contaminated soil or mineral waste. The mandatory parameters typically include: dry matter content (TS), loss on ignition, pH value, total sulfur content, and chloride and fluoride content. These values are decisive for assessing thermal treatability.
- Dry matter content (TS): Determines the water content and directly influences energy demand in the rotary kiln.
- Loss on ignition: Provides information on the organic fraction and thus on the level of contamination.
- pH value: Relevant for assessing the material’s reaction during treatment.
- Total sulfur content: High sulfur levels can place a burden on exhaust gas purification and are therefore relevant from a plant engineering perspective.
- Chloride and fluoride content: Decisive for the formation of dioxins and the design of exhaust gas purification.
Depending on the type of waste, additional parameters such as heavy metal contents (e.g., lead, cadmium, arsenic) or calorific value may be added. This information enables the treatment facility to reliably assess material behavior in the rotary kiln — which operates at temperatures of up to approximately 600 °C, depending on the material and contaminant load — and in the exhaust gas purification system.
According to which standards and regulations must sampling be carried out?
Sampling for a declaration analysis must be carried out in accordance with recognized technical standards to ensure the representativeness of the results. In Germany, the DIN EN ISO 10381 series for soil sampling and LAGA PN 98 (guidelines for procedures in physical, chemical, and biological investigations) are particularly authoritative. For waste, the requirements of the Landfill Ordinance (DepV) and the Waste Catalogue Ordinance (AVV) also apply.
Sampling must be planned and carried out in such a way that it captures the actual contamination pattern of the material. This means: a sufficient number of individual samples, proper composite sample formation, and complete documentation of sampling points. For heterogeneously contaminated materials, as frequently encountered in remediation projects, particularly careful sampling planning is required.
The analytical methods themselves must also comply with standards, such as DIN EN ISO or the DIN 38000 series for water and soil analysis. Deviations from recognized standards must be justified and documented.
Who is authorized to prepare a declaration analysis for thermal treatment?
A declaration analysis for thermal treatment may only be prepared by accredited testing laboratories. Accreditation in accordance with DIN EN ISO/IEC 17025 by the German Accreditation Body (DAkkS) is a prerequisite for the analytical results to be officially recognized and to serve as the basis for disposal decisions.
Sampling itself must be carried out by qualified personnel familiar with the relevant standards. In practice, this is frequently performed by expert assessors, engineering firms, or remediation companies with the appropriate qualifications. It is important that sampling and analysis are clearly documented and that the results are summarized in a comprehensible test report.
Non-accredited laboratories or self-analyses without appropriate qualifications are generally not accepted by disposal facilities. This applies in particular when disposal requires approval or is subject to regulatory supervision.
What happens if the declaration analysis is incomplete or flawed?
If the declaration analysis is incomplete or flawed, the delivery will be rejected by the treatment facility or put on hold until complete and correct documentation is available. In the worst case, delays in the remediation project can occur, causing significant additional costs.
Missing contaminant parameters can result in waste being incorrectly classified. This poses risks for plant operation, exhaust gas purification, and compliance with emission limit values. Thermal desorption plants are designed for specific contaminant profiles. Unknown or undeclared constituents can disrupt operations or, in the worst case, lead to emissions that exceed statutory limit values.
Legally, the waste producer or waste holder bears responsibility for correct declaration. A flawed declaration analysis can result in regulatory consequences, particularly if the waste was thereby improperly disposed of. Careful and complete contaminant analysis is therefore not merely a formal obligation, but an essential contribution to legal certainty for all parties involved.
How does the declaration analysis differ depending on the type of waste?
The scope and focus of the declaration analysis vary considerably depending on the type of waste. Different requirements regarding sampling, parameter scope, and assessment criteria apply to contaminated soil, dredged material, construction rubble, or process residues such as slags, ashes, and sludges.
Contaminated soil and dredged material
For soils from remediation projects, the site-specific contamination history is the primary focus. The analysis program is guided by the previous use of the property. PAHs, MKW, and BTEX are standard at gasworks sites. At military sites, nitroaromatics or explosive residues may be relevant. For dredged material from bodies of water, heavy metals and PCBs are frequently added.
Construction rubble and mineral process residues
For construction rubble, in addition to organic contamination, the content of hazardous mineral fibers or asbestos must also be examined before thermal treatment is considered. Process residues such as slags or ashes frequently exhibit complex inorganic contaminant profiles. Here, in addition to organic contaminants, heavy metal contents and leaching behavior as determined by eluate analyses are particularly relevant.
Material flow management always begins with a complete characterization of the waste. Only on this basis can the appropriate disposal route be determined and it can be ensured that the material is treated properly and without causing harm.
How ARE Deutzen supports with declaration analysis and thermal treatment
ARE Deutzen GmbH supports customers from civil and structural engineering as well as industry in the safe disposal of contaminated mineral waste. With over 30 years of experience in thermal desorption and the operation of a high-performance facility at the Deutzen site, ARE provides a reliable foundation for demanding remediation projects. Specifically, ARE Deutzen provides support with:
- Review and assessment of submitted declaration analyses for completeness and plausibility
- Feedback on missing parameters or necessary follow-up investigations
- Acceptance and thermal treatment of soils, construction rubble, and process residues with complex contamination profiles
- Coordination of disposal via in-house material flow management, including for waste fractions that cannot be thermally treated
- Transparent communication regarding acceptance conditions and required documentation
Anyone wishing to submit a declaration analysis or clarify in advance whether a material is suitable for thermal treatment should contact the contact persons at ARE Deutzen directly. Early coordination saves time and avoids unnecessary delays in the course of the project.