The journey of a soil batch through a thermal treatment facility can be traced at every process step through seamless documentation. From acceptance through mechanical pre-treatment to final analysis, all relevant data is recorded, documented, and compiled into verification documents. The following sections answer the most important questions about batch traceability and documentation in thermal soil treatment.
What data is recorded when a soil batch is accepted?
When a soil batch is accepted, its origin, quantity, waste code, contaminant characteristics, and accompanying documents are systematically recorded. The basis for this is the accompanying document and verification procedure in accordance with the Waste Verification Ordinance (NachwV), which is mandatory for hazardous waste in Germany. Each batch receives a unique identification number that accompanies it throughout the entire treatment process.
In detail, the incoming registration includes the following information:
- Waste generator and site of origin
- Waste code number according to the European Waste Catalogue (EWC)
- Delivered quantity in tonnes
- Existing analysis results from the client
- Classification as hazardous or non-hazardous waste
- Accompanying document or acceptance receipt
Prior to final acceptance, an incoming inspection is typically carried out. During this inspection, the delivered material is visually assessed and compared with the information in the accompanying documents. In the event of discrepancies or unclear characteristics, additional analyses are ordered before the batch is introduced into the treatment process. This intake phase is critical because all subsequent verification is built on the basic data recorded here.
How is a batch tracked through mechanical pre-treatment?
During mechanical pre-treatment, the batch continues to be tracked under its identification number. Screening, crushing, and, where applicable, homogenization are documented, including the sub-quantities produced and their properties. This ensures that traceability is maintained even when a delivery is split into multiple treatment batches.
The mechanical-physical treatment serves not only to prepare the material for the rotary kiln, but also for quality assurance. Oversized material, foreign matter, or non-treatable components are sorted out at this stage and recorded separately. Their disposal is also documented, ensuring that no sub-quantity of the original delivery remains undocumented.
What parameters are recorded during thermal desorption?
During thermal desorption, process temperature, residence time in the rotary kiln, oxygen content in the kiln chamber, and the emission values of the exhaust gas purification system are continuously recorded. These operating parameters form the technical core of batch traceability and demonstrate that treatment took place under the prescribed conditions.
In the rotary kiln, the material is treated at temperatures of up to approximately 600 °C, depending on the material and contaminant load. Thermal desorption converts organic contaminants such as TPH, BTEX, PAH, PCB, PFAS, or PCDD/PCDF into the gaseous state. The subsequent multi-stage exhaust gas purification with thermal post-combustion, flue gas scrubbing, and activated carbon filtration ensures that these contaminants are completely destroyed. All steps of this thermal soil treatment are seamlessly recorded by process control systems.
The recorded parameters typically include:
- Kiln temperature and temperature profile over the entire treatment period
- Residence time of the material in the kiln
- Oxygen content in the kiln chamber as proof of anaerobic operation
- Emission measurement values for relevant contaminants in the exhaust gas
- Throughput quantity per unit of time
These data are stored on a batch-specific basis and, together with the analysis results, form the basis for the treatment verification.
How is the treatment success of a batch analytically verified?
Treatment success is verified through laboratory analyses of the treated material. Representative samples are taken from the output material and tested for the relevant contaminants. The results must fall below the agreed target values in order to provide proof of successful treatment.
Sampling is carried out in accordance with recognized sampling procedures to ensure that the analysis is statistically reliable. Depending on the contaminant spectrum and the intended use of the treated material, different parameters are examined. For soils intended for recovery after treatment, the target values are based on the requirements of the Federal Soil Protection and Contaminated Sites Ordinance (BBodSchV) or on project-specific specifications from the client.
Accredited laboratories carry out the analyses and issue test reports, which are included in the documentation as independent confirmation of treatment success. This step is critical for the legal protection of all parties involved — namely the client, the facility operator, and the responsible authorities.
What verification documents are produced at the end of the treatment process?
At the end of the treatment process, a complete set of documentation is produced that provides seamless evidence of the soil batch’s journey from acceptance to handover of the treated material. The key documents include the acceptance receipt, treatment protocol, analysis certificate, and disposal verification.
In detail, the documentation set includes:
- Acceptance receipt or accompanying document as proof of proper acceptance
- Weighing slip with the exact incoming quantity
- Treatment protocol with the recorded process parameters
- Analysis certificate from the accredited laboratory for the treated material
- Disposal verification in accordance with the Waste Verification Ordinance
- Delivery note for the transport of the treated material
These documents are archived for the legally required retention periods. The client typically receives a copy of the relevant documents, which can be submitted to authorities or used in the context of contaminated site documentation. A complete set of documentation is therefore not only a legal obligation, but also a practical added value for remediation planning.
What happens if a batch does not meet the quality criteria?
If a batch does not meet the agreed quality criteria after treatment, it is not released. Instead, the material is subjected to re-treatment or transferred to an alternative disposal route. This step is also fully documented so that the chain of evidence is not interrupted at any point.
The most common causes of insufficient treatment quality are excessively high initial contamination, an inhomogeneous batch composition, or technical deviations in the process. In such cases, the process parameters are analyzed and adjusted as necessary before the material is treated again. The quality management system, which is certified to ISO 9001 and ISO 14001, prescribes clear escalation processes and corrective measures.
For the client, this means: even in exceptional cases, the documentation remains complete and traceable. No material leaves the facility without verified proof of its treatment and subsequent whereabouts. More information on quality assurance within the framework of quality management can be found in the relevant section of the company website.
How ARE Deutzen GmbH ensures the documentation of your soil batch
ARE Deutzen GmbH supports clients from civil engineering, industry, and the public sector in the legally compliant documentation of contaminated soil batches from acceptance through to final verification. The company combines over 30 years of experience in thermal soil treatment with a certified quality management system and the required permit under the Federal Immission Control Act.
The services in the area of documentation and verification specifically include:
- Complete incoming registration and creation of accompanying documents in accordance with the NachwV
- Seamless recording of all process parameters during thermal desorption
- Sampling and analysis of the treated material by accredited laboratories
- Preparation of a complete documentation set for each client
- Clear processes for re-treatment or alternative disposal in the event of quality deviations
- Support with material flow management for complex remediation projects
If you are remediating a contaminated site and require reliable, authority-compliant documentation, contact ARE Deutzen GmbH directly. Their specialists will provide concrete advice on your project and the applicable documentation requirements.