Contaminants affect thermal soil treatment by disrupting rotary kiln operation, jeopardizing pollutant destruction, and in severe cases leading to the rejection of a material. What matters most is the type of foreign material present in the soil and its concentration. The following sections answer the most important questions about contaminants in thermal desorption.

What materials are considered contaminants in soil treatment?

All materials that negatively affect the mechanical pre-treatment process or the operation of the rotary kiln are considered contaminants in thermal soil treatment. These include primarily coarse foreign matter such as metal parts, cables, plastics, wood residues, construction debris with a high concrete content, and coarse organic fractions such as roots or plant residues.

Particularly problematic are materials that are either difficult to shred or exhibit undesirable behavior in the kiln. Metal scrap can mechanically damage the conveyor system and the rotary kiln. Plastics and cables combust at process temperatures, generating combustion products that place a burden on the exhaust gas cleaning system. Coarse construction debris with concrete fragments exceeding the permitted grain size can disrupt the uniform material flow in the kiln.

High proportions of organic matter, such as peat or heavily humic material, are also considered a disruptive factor, as they alter the energy requirements of the process and make controlling the process temperature more difficult. The mechanical-physical pre-treatment aims to largely remove such contaminants before kiln operation.

How do contaminants impair the rotary kiln?

Contaminants in the rotary kiln impair the process on multiple levels: they can cause mechanical damage, reduce heat transfer to the contaminated material, and lead to uneven temperatures within the kiln chamber. All of this directly affects the quality of pollutant destruction.

Metallic foreign objects that have not been fully removed can damage the inner lining of the rotary kiln and, in the worst case, lead to unplanned plant shutdowns. Coarse-grained material that does not conform to the prescribed grain size is not uniformly mixed and heated in the rotating kiln. The result is localized temperature fluctuations that can render thermal treatment incomplete in certain material areas.

Plastics and other combustible contaminants alter the heat balance in the kiln, as they release energy themselves. This makes it more difficult to precisely control the process temperature, which must be maintained within a defined range during thermal desorption in order to safely destroy pollutants or convert them to a gaseous state.

What happens to pollutants when contaminants disrupt the temperature?

When contaminants disrupt the temperature distribution in the rotary kiln, there is a risk that individual material areas do not reach the required treatment temperature. In these areas, pollutants such as mineral oil hydrocarbons, PAHs, or chlorinated hydrocarbon compounds may be incompletely destroyed or driven off.

Thermal desorption works on the principle that pollutants are either destroyed or converted to a gaseous state at sufficiently high temperatures and under oxygen exclusion, where they are subsequently captured and treated in the multi-stage exhaust gas cleaning system. If this temperature range is locally undershot, some of the pollutants remain bound in the solid material.

In this case, the treated material would not meet the requirements for a low-contaminant feedstock for recycling or landfill disposal. For this reason, controlling and minimizing contaminants is not only a technical requirement but also a quality assurance necessity. Quality assurance in the treatment process therefore begins at the point of material acceptance and characterization of the input material.

How are contaminants removed before thermal treatment?

Contaminants are removed before thermal treatment through a multi-stage mechanical pre-treatment process. This typically includes screening, shredding, and magnetic separation to bring the material to a suitable grain size and remove foreign objects.

In the first step, the delivered material is screened to separate coarse fractions that exceed the permitted grain size for the rotary kiln. Oversized material is either shredded or, if it cannot be treated, disposed of separately. Magnetic separators remove metallic foreign objects from the material stream before it is fed into the kiln.

Additionally, air classification or wet processing can be used to separate light organic components or other specific contaminants. The appropriate combination of methods depends on the composition and origin of the material. For complex materials from remediation projects or decommissioned industrial sites, careful preliminary investigation and characterization of the input material is essential.

Which contaminants cannot be completely removed?

Some contaminants cannot be completely removed by mechanical pre-treatment because they are finely distributed throughout the soil or are closely intergrown with the mineral material. These include, among others, finely distributed plastic particles, tar components, and certain inorganic compounds.

Fine-grained plastic fractions, such as those from the degradation of films or pipe materials, cannot be completely separated by screening, as they may have similar grain sizes to the mineral material. Heavily tar-laden soils, such as those found at former gasworks sites, contain organic binders that are bonded to the soil particles and cannot be mechanically separated.

Inorganic contaminants such as elevated sulfate levels or certain heavy metal compounds are not destroyed by thermal desorption, as these compounds only react at significantly higher temperatures. They remain in the treated material and must be taken into account when assessing the recyclability of the output material. Material flow management plays an important role here in finding the appropriate disposal route for each material stream.

When is a soil unsuitable for thermal desorption due to contaminants?

A soil is unsuitable for thermal desorption when contaminants are present in a type or concentration that prevents safe and proper treatment in the rotary kiln or jeopardizes the plant’s emission limits. This is particularly the case with very high plastic content, significantly elevated chlorine levels, or explosive materials.

Soils with very high levels of halogenated compounds, particularly chlorine-containing plastics such as PVC, can lead to overloading of the exhaust gas cleaning system during thermal treatment. Although the plant is approved for treating soils containing chlorinated hydrocarbon compounds, there are limits on the permissible input concentration of certain compound classes.

Materials with a very high proportion of non-mineral components, such as heavily organically contaminated sludges with low solids content, or soils with explosive residues from military installations, also require a separate assessment. In such cases, alternative treatment or a combination of pre-treatment and thermal desorption may be necessary.

A reliable assessment of suitability always requires complete material characterization, including pollutant analysis, grain size distribution, and determination of the relevant contaminant fractions.

How ARE Deutzen GmbH helps with contaminants in thermal soil treatment

ARE Deutzen GmbH has more than 30 years of experience in treating complex contaminated soils and mineral waste. The company offers a proven solution for projects where contaminants complicate thermal desorption:

  • Material characterization and suitability assessment: Before acceptance, every material is examined for its composition, pollutant load, and contaminant fractions to determine the appropriate treatment path.
  • Mechanical-physical pre-treatment: Screening, shredding, and magnetic separation specifically prepare the input material for the rotary kiln and minimize disruptive foreign objects.
  • Thermal desorption in the rotary kiln: Thermal soil treatment takes place at temperatures of up to approximately 600 °C, depending on the material and pollutant load, under oxygen exclusion with multi-stage exhaust gas cleaning.
  • Material flow management: For materials that cannot be thermally treated or can only be partially treated, alternative disposal routes are organized through the company’s own network of partner facilities.
  • Certified waste management company: ARE Deutzen GmbH operates in accordance with ISO 9001, 14001, 50001, and 18001 and is certified under the Circular Economy Act.

If you are planning a remediation project and are unsure whether your material is suitable for thermal desorption, speak directly with the experts at ARE Deutzen GmbH. Contact us now and have your material assessed without obligation.