What Are the Components of a Stationary Thermal Soil Treatment Plant?

Markus Reichenbach ·

A stationary thermal soil treatment plant consists of several coordinated main components: a rotary kiln as the central treatment unit, a mechanical pre-treatment stage, a multi-stage exhaust gas cleaning system, and systems for material feed, dust removal, and final storage of the treated material. All components are technically interconnected and together ensure safe, legally compliant treatment of contaminated mineral waste. The following sections answer the most important questions about the technology, licensing, and operation of such plants.

How does a thermal desorption plant work technically?

A thermal desorption plant heats contaminated soils and mineral waste in a rotary kiln to temperatures of up to approximately 600 °C, largely under exclusion of oxygen. This means organic contaminants are not incinerated but evaporated or thermally destroyed. The resulting pollutant gases are then treated in a downstream exhaust gas cleaning system.

The process of thermal soil treatment specifically exploits the physical transition of contaminants into the gaseous state. At sufficiently high temperatures, volatile and semi-volatile organic compounds detach from the mineral grain structure. Since the process is conducted under low-oxygen conditions, no uncontrolled combustion takes place. Instead, the released contaminants are completely oxidized and destroyed in a thermal post-combustion chamber at significantly higher temperatures.

The rotary kiln rotates continuously, ensuring the material is evenly mixed and heated. The residence time in the kiln is designed so that even difficult-to-reach contaminants are reliably released. Temperature, residence time, and oxygen content are the three central control parameters, which are adjusted according to the contaminant profile and material composition.

What are the main components of a stationary plant?

A stationary thermal soil treatment plant typically comprises six functional main components: reception and mechanical pre-treatment, material feed, rotary kiln, thermal post-combustion, multi-stage exhaust gas cleaning, and systems for emission discharge and monitoring. Each component fulfills a defined function in the overall process.

  • Reception and mechanical pre-treatment: Delivered material is first inspected, classified, and if necessary crushed or screened. Oversized material and interfering substances are removed to ensure a uniform material flow into the kiln.
  • Material feed: Dosing units feed the pre-treated material in a controlled manner into the rotary kiln. Uniform input is a prerequisite for stable process temperatures.
  • Rotary kiln: The heart of the plant. This is where the actual thermal desorption takes place. The rotating kiln ensures even heat distribution and sufficient residence time of the material.
  • Thermal post-combustion: The pollutant gases discharged from the rotary kiln are completely oxidized in an afterburner chamber at high temperatures. This step is critical for the destruction of persistent organic compounds.
  • Exhaust gas cleaning: A multi-stage cleaning line consisting of dust removal, flue gas scrubbing, and activated carbon filters removes dust, acidic gases, and residual contaminants from the exhaust gas before it is discharged via the stack.
  • Emission monitoring: Continuous measurement technology monitors exhaust gas values in real time and ensures compliance with statutory limit values.

Which contaminants can a thermal soil treatment plant treat?

Stationary thermal soil treatment plants are approved for a wide range of organic and inorganic contaminants. Typical contaminants include mineral oil hydrocarbons (MKW), BTEX compounds, polycyclic aromatic hydrocarbons (PAH), polychlorinated biphenyls (PCB), phenols, cyanides, nitroaromatics, and persistent organic pollutants such as PFAS, PFOS, and dioxins (PCDD/PCDF). Mercury (Hg) and a large number of chlorinated hydrocarbon compounds can also be treated.

The wide range of treatable contaminants makes thermal desorption particularly valuable for complex remediation cases where multiple contaminants are present simultaneously. Decommissioned gasworks sites, for example, are frequently contaminated with PAH and cyanides, while former industrial sites often exhibit mixtures of chlorinated solvents and heavy metals.

It is important that the contaminant profile is analytically recorded before treatment. Based on this characterization, treatment temperature and process management are individually adjusted to ensure complete contaminant destruction.

What happens to the treated material after desorption?

After thermal treatment, the material is present as a cleaned mineral mixture that generally meets the statutory limit values for recovery or controlled disposal. Depending on the source material and treatment result, it can be recycled as a construction material or fill material, or properly landfilled.

The treated material is cooled after removal from the rotary kiln and analytically sampled. Only once the laboratory results confirm compliance with the relevant limit values is a decision made about its further disposition. Recycling as a secondary material is ecologically sound and reduces the demand for primary raw materials.

As part of a structured material flow management system, the entire material flow is documented and tracked. This includes reception, treatment, sampling, and recovery or disposal of the final material, ensuring complete proof of compliance for authorities and clients.

What approvals and certifications are required for operation?

Operating a stationary thermal soil treatment plant requires an immission control permit under the Federal Immission Control Act (BImSchG). In addition, certifications to ISO 9001 (quality management), ISO 14001 (environmental management), and recognition as a certified waste management company (EfB) in accordance with the Circular Economy Act are standard requirements for reputable plant operators.

The BImSchG permit specifies, among other things, the approved waste types, treatment volumes, and emission limit values in a binding manner. It forms the legal basis for operation and protects residents and the environment through clear conditions. Changes to operations or to the types of waste treated generally require an amendment to the permit.

Certification to ISO 50001 (energy management) and ISO 18001 (occupational health and safety) goes beyond the minimum statutory requirements and documents a systematic management system. For clients, EfB recognition is an important quality indicator that certifies the proper and competent disposal of contaminated waste. More information about the requirements for structured quality management can be found in the relevant section of the ARE Deutzen GmbH website.

When should a stationary plant be preferred over a mobile solution?

A stationary thermal soil treatment plant is preferable when large quantities of material, complex contaminant mixtures, or particularly high contamination concentrations are involved. Mobile plants are flexible in their deployment, but reach technical and regulatory limits when faced with demanding contaminant profiles and high throughput.

Specifically, the following factors favor the use of a stationary plant:

  • High material throughput: Stationary plants are designed for continuous operation with large volumes and are more economically efficient for projects involving several thousand tonnes or more.
  • Complex contaminations: Multiple contaminations with persistent pollutants such as PCDD/PCDF, PCB, or PFAS require precisely controllable process parameters and high-performance exhaust gas cleaning.
  • High quality requirements: Stationary plants are equipped with extensive measurement technology and quality assurance systems that are often not available to the same depth in mobile units.
  • Regulatory certainty: A permanently installed, officially approved plant provides clear legal certainty for clients and facilitates proof of compliance.

Mobile solutions make sense when the site is difficult to access, the volume of material is small, or transporting the soil is not feasible for other reasons. For most large-scale brownfield remediation projects, however, the stationary plant offers the more reliable and technically superior solution.

How ARE Deutzen GmbH supports thermal soil treatment

ARE Deutzen GmbH has been operating a stationary thermal soil treatment plant at its Deutzen site in western Saxony since 1994 and has more than 30 years of experience in treating complexly contaminated mineral waste. The plant is approved under BImSchG, certified to ISO 9001, 14001, 50001, and 18001, and recognized as a certified waste management company.

For civil engineering companies, project developers, and industrial clients, ARE Deutzen GmbH specifically offers:

  • Thermal desorption of contaminated soils, demolition rubble, and mineral waste in a rotary kiln at temperatures of up to approximately 600 °C, depending on the material and contaminant load
  • Treatment of a wide range of contaminants, including MKW, PAH, PCB, PFAS, dioxins, and mercury
  • Multi-stage exhaust gas cleaning with dust removal, thermal post-combustion, flue gas scrubbing, and activated carbon filters
  • Complete material flow management from reception through to recovery or disposal of the treated material
  • Comprehensive documentation and regulatory-compliant proof of compliance

If you are planning a remediation project or need to safely dispose of contaminated material, contact ARE Deutzen GmbH directly. The contacts at ARE Deutzen GmbH will advise you on feasibility, regulatory requirements, and project workflow. Get in touch now and receive an expert initial assessment for your project.