Three factors primarily determine whether a material can be thermally treated: the type and concentration of contaminants present, the water content, and the particle size of the source material. In addition, organic components can influence the process, and certain material properties fundamentally rule out thermal desorption. The following sections answer the most important questions about material suitability in detail.
Which contaminants can be removed by thermal desorption?
Thermal desorption is suitable for a broad range of organic and inorganic contaminants that are volatile or thermally decomposable. These include mineral oil hydrocarbons (MOH), BTEX compounds, phenols, polycyclic aromatic hydrocarbons (PAH), polychlorinated biphenyls (PCB), PFAS and PFOS, dioxins and furans (PCDD/PCDF), cyanides, nitroaromatics, and numerous other chlorinated hydrocarbon compounds. Mercury (Hg) can also be removed from soil using this process.
The key factor is that these contaminants are either destroyed or converted to a gaseous state at the temperatures of up to approximately 600 °C prevailing in the rotary kiln. Treatment takes place under oxygen exclusion, which prevents uncontrolled combustion and simultaneously ensures that contaminants are completely driven out of the solid material. The resulting contaminated gas is then cleaned in a multi-stage thermal treatment plant before being released into the atmosphere.
The process is particularly relevant for sites of former gasworks, industrial brownfields, and military or chemical facilities, where contaminant mixtures from several of the aforementioned substance classes are present.
How does water content affect treatability?
The water content of a material has a direct influence on the efficiency of thermal desorption. Excessively high water content significantly increases energy consumption, as the water must be evaporated before the actual contaminant expulsion phase. Soils with a water content well above 25 to 30 percent are generally only treatable to a limited extent or after mechanical pre-drying.
Overly wet materials also clump together in the rotary kiln, which impairs uniform material transport and homogeneous heat distribution. The result is uneven treatment temperatures and thus potentially incomplete contaminant removal. In practice, water content is therefore measured and assessed at the point of acceptance.
Conversely, excessively low water content can also be problematic for certain materials, for example when dusty fractions arise that place a burden on the process and the exhaust gas purification system. Mechanical pre-treatment, including mixing and conditioning, helps to bring the water content into a technically appropriate range.
Why is the particle size of the material decisive?
Particle size significantly influences how uniformly heat can penetrate the material and how effectively contaminants are driven out of the solid. Coarse-grained materials with particle sizes above 80 to 100 millimeters must be crushed prior to thermal treatment, as heat transfer into the interior of the particles would otherwise be insufficient and contaminants may remain in the core area.
Fine-grained materials such as silts or clays present a different challenge: they tend to agglomerate and can stick together in the rotary kiln, which impairs material throughput and treatment quality. Sandy soils with particle sizes between one and ten millimeters are considered particularly well suited, as they offer a high surface area combined with good mixability.
Mechanical pre-treatment — that is, screening, crushing, and homogenizing the feed material — is therefore an essential step before the actual thermal treatment. Further information on mechanical-physical treatment shows how this step is implemented in practice.
Which organic components can make treatment more difficult?
High proportions of organic matter in the soil, such as humus, peat, or organic process residues, can significantly complicate thermal desorption. These materials combust or gasify at treatment temperatures, leading to increased oxygen demand and making process control under oxygen exclusion more difficult. In addition, larger volumes of exhaust gas are produced, placing a burden on the capacity of the exhaust gas purification system.
Materials with a loss on ignition of more than 10 to 15 percent are particularly critical. In such cases, it must be assessed whether pre-treatment, blending with less organically contaminated material, or an alternative disposal method is more appropriate. Tar and pitch residues present in high concentrations can also burden the plant through clogging and increased contaminant discharge in the exhaust gas.
Materials with low organic content and clearly defined contaminant profiles, on the other hand, can be treated very efficiently. Precise characterization of the organic fraction is therefore part of every incoming analysis.
Which materials are fundamentally unsuitable for thermal desorption?
Materials whose contaminants are neither volatile nor thermally decomposable are not suitable for thermal desorption. Heavy metals such as lead, cadmium, arsenic, or chromium are firmly bound in mineral soils and are not removed by heating; at most, their binding form is altered. These metals remain in the treated material and may even become concentrated.
Materials with very high salt content are also unsuitable, as these place a corrosive burden on the exhaust gas purification system and plant components. Strongly alkaline or acidic materials, as well as materials with unknown or highly variable composition, require particularly careful pre-screening and are frequently not directly acceptable.
Radioactively contaminated materials and waste subject to radiation protection legislation are fundamentally excluded from thermal desorption and must be disposed of via specialized facilities. The same applies to materials that can generate explosive gases or whose treatment would lead to uncontrollable reactions in the kiln.
How is a material’s suitability assessed prior to acceptance?
Before a material is accepted, every project undergoes a structured incoming analysis based on waste data sheets, analytical certificates, and contaminant assessments. The type and concentration of contaminants, water content, particle size distribution, organic content, and any potentially disruptive constituents are all evaluated. Only when these parameters allow for safe and proper operation is the material approved for treatment.
In practice, the suitability assessment comprises the following steps:
- Evaluation of existing analyses and assessments of the contaminant profile
- Screening for non-treatable constituents (e.g. heavy metals, salts, radioactivity)
- Assessment of water content and particle size with regard to plant suitability
- Estimation of loss on ignition and organic content
- Where necessary, request for additional samples and laboratory analyses
- Coordination with the relevant authorities for special contaminant profiles
Material flow management plays an important role in this process: depending on the analytical results, a decision is made as to whether the material is treated directly at the in-house facility, mechanically pre-treated, or transferred to a partner operation. This structured approach ensures treatment quality and protects the plant from incompatible materials. For questions regarding material suitability, the team is available via the contact page.
How ARE Deutzen GmbH assists in assessing thermal treatability
ARE Deutzen GmbH has more than 30 years of experience in the assessment and treatment of contaminated mineral waste. The company supports civil engineering firms, project managers, and industrial clients in reliably evaluating the treatability of their materials and identifying the appropriate disposal route. The range of services includes:
- Expert evaluation of analytical data and contaminant assessments
- Clear statement on acceptability based on defined incoming parameters
- Mechanical pre-treatment to optimize water content and particle size
- Thermal desorption in the rotary kiln at up to approximately 600 °C under oxygen exclusion
- Material flow management for materials that cannot be treated directly
- Certified operation in accordance with ISO 9001, 14001, 50001 and as a certified waste management company under the KrWG
If you are unsure whether your material is suitable for thermal desorption, please get in touch directly. ARE Deutzen GmbH will review your documentation and provide you with a well-founded, binding assessment.