Thermal desorption is a powerful method for treating contaminated soils, but it reaches its limits with certain pollutants, material properties, and economic conditions. Not every contamination can be eliminated through heat treatment, and not every material is suitable for use in a rotary kiln. The following sections highlight the most important limitations of thermal soil treatment and show when alternative or complementary methods are more appropriate.
Which pollutants cannot be eliminated by thermal desorption?
Thermal desorption fundamentally cannot destroy inorganic pollutants such as heavy metals. While organic compounds evaporate or decompose at sufficiently high temperatures, metals such as lead, arsenic, chromium, or zinc remain in the solid material. Mercury is an exception, as its low boiling point allows it to be driven out of the soil through desorption.
Pollutants such as cyanides, nitroaromatics, PAHs, BTEX, TPH, PCBs, PFAS, and chlorinated hydrocarbons can be reliably removed or decomposed from the soil through thermal treatment. With heavy metals, however, heat treatment only changes the binding form within the solid material, not the concentration. The treated material must subsequently be tested for pollutant levels before a decision can be made about recovery or disposal. Soils with high heavy metal concentrations therefore require supplementary or alternative treatment methods.
At what pollutant concentration does thermal desorption reach its limits?
Thermal desorption has no rigid upper limits for pollutant concentrations, but very high concentrations can strain plant capacity, exhaust gas purification, and economic viability. Extremely heavily contaminated materials require longer residence times in the rotary kiln or must be blended with less contaminated material prior to treatment to ensure uniform and compliant processing.
What matters is not only the concentration, but also the nature of the pollutant’s binding within the soil. Compounds strongly bound to clay minerals or organic soil matter are harder to mobilize than those in sandy, permeable soils. In addition, the volumes of exhaust gases produced must be safely manageable by the multi-stage exhaust gas purification system. Very high organic pollutant concentrations can place a significant burden on the thermal afterburner, which effectively limits treatment capacity.
Which material properties restrict treatment in the rotary kiln?
Materials with high water content, coarse components, or sticky properties restrict treatment in the rotary kiln. Very moist material first requires extensive pre-drying, as excessive moisture greatly increases energy consumption and negatively affects treatment temperature. Coarse pieces such as demolition rubble or concrete fragments must be mechanically crushed before being fed into the kiln.
Additional limiting factors include:
- Particle sizes exceeding the permissible maximum: Large chunks do not reach the necessary treatment temperature in their interior and must be pre-crushed.
- Sticky or plastic materials: Clays or silty soils with a high fine-grain content tend to clump together in the rotary kiln and can disrupt operations.
- High loss on ignition: Materials with a very high organic content can react uncontrollably if adequate oxygen control is not ensured.
- Melting components: Materials that melt or sinter at treatment temperatures can damage the kiln lining.
Careful mechanical pre-treatment is therefore an essential part of the overall process. The mechanical-physical treatment prepares the material so that it meets the requirements of the rotary kiln.
When is thermal desorption not the most cost-effective remediation method?
Thermal desorption is not the most cost-effective method when the level of contamination is very low, the volume is very small, or less expensive in-situ methods are technically suitable. For lightly contaminated soils that fall below applicable threshold values for recovery, extensive thermal treatment is often disproportionate.
The following situations tend to argue against the use of thermal desorption:
- Very small quantities of pollutants, where soil washing or biological remediation is more cost-efficient
- Sites with exclusively inorganic heavy metal contamination that cannot be eliminated through desorption
- Large volumes of lightly contaminated soils, where relocation to a landfill may be more economically advantageous
- Situations where in-situ remediation completely avoids soil excavation and transport
The decision for or against thermal soil treatment always depends on an overall assessment that takes into account the type of pollutant, volume, transport routes, recovery options, and regulatory requirements.
What happens to the treated material after thermal desorption?
After thermal desorption, the treated material is tested for pollutant levels and structural engineering properties. If it meets the applicable requirements, it can be recovered as a recycled construction material, for example as fill material in road or earthwork construction. Otherwise, controlled landfill disposal is required.
The recoverability of the treated material depends on several factors: the original pollutant spectrum, the residual content after treatment, and the material properties such as load-bearing capacity and compactability. For soils that contain elevated heavy metal levels in addition to organic pollutants, recovery is often restricted or excluded. A well-conceived material flow management system ensures that material streams are properly directed after treatment.
Are there legal limits for the operation of thermal desorption plants?
Yes, thermal desorption plants are subject to strict legal requirements. In Germany, they require approval under the Federal Immission Control Act (BImSchG) and must comply with defined emission limit values for exhaust gases. The 17th BImSchV regulates the requirements for exhaust gas purification and sets limit values for pollutants such as dioxins, furans, nitrogen oxides, and dust.
Operators are required to continuously monitor and document compliance with these limit values. A multi-stage exhaust gas purification system with dust removal, thermal afterburning, flue gas scrubbing, and activated carbon filtration is therefore technically necessary, not optional. In addition, requirements from the Circular Economy Act (KrWG) apply to waste acceptance and proof of proper disposal. Certifications to ISO 9001, 14001, and 50001 are not a legal obligation, but are recognized as proof of quality by clients and authorities. Operating such a facility also requires authorization as a certified waste management company under § 52 KrWG. More on ARE Deutzen’s quality management shows how these requirements are implemented in practice.
How ARE Deutzen GmbH helps with the limitations of thermal desorption
ARE Deutzen GmbH has more than 30 years of experience in treating complexly contaminated soils and knows the limits of thermal desorption from daily practice. The company evaluates each material stream individually and develops the appropriate treatment strategy on that basis, even when thermal soil treatment alone is not sufficient.
Specifically, ARE Deutzen offers:
- Expert incoming characterization and assessment of the treatability of waste and soils
- Mechanical-physical pre-treatment to prepare difficult materials prior to thermal treatment
- Thermal desorption in a rotary kiln at up to approximately 600 °C, depending on the material and pollutant load, for a broad spectrum of organic pollutants
- Material flow management for materials that cannot be thermally treated, including referral to suitable partner facilities
- Interim storage and documentation as part of a complete waste disposal verification
If you are unsure whether your contaminated soils are suitable for thermal treatment, contact ARE Deutzen directly. The on-site experts will help you find the right solution for your remediation project.