Thermal desorption is fundamentally suitable for blast sand and foundry sand, provided the contaminants present are thermally volatile or destructible and the sand meets the mechanical requirements of the facility. Both sand types are classified as mineral waste and can be treated in a rotary kiln system at appropriate temperatures. The following sections explain which contaminants typically occur, how the treatment works, and what to consider during disposal.
Which contaminants are typically found in blast sand and foundry sand?
Blast sand is frequently contaminated with heavy metals such as lead, zinc, or cadmium, which transfer into the sand during blasting of old coatings and corrosion protection layers on steel or concrete surfaces. Foundry sand, by contrast, often contains organic contaminants such as polycyclic aromatic hydrocarbons (PAH), phenols, and mineral oil hydrocarbons (MOH), originating from the binders and coating materials used.
The following contaminant groups are specifically relevant:
- Blast sand: Heavy metals (Pb, Zn, Cd, Cr, Cu), mineral oil hydrocarbons from lubricants, occasionally PCBs from older corrosion protection coatings
- Foundry sand: PAHs from bitumen and carbon binders, phenols from synthetic resin binders, MOH, BTEX compounds, and occasionally cyanides from certain molding sand processes
The exact contaminant composition depends heavily on the source process. A representative analysis is therefore required before any disposal to fully capture the waste characteristics and determine the correct treatment pathway.
How does thermal desorption work for mineral sands?
In thermal desorption, the contaminated sand is heated in a rotary kiln under oxygen exclusion to temperatures of up to approximately 600 °C, depending on the material and contaminant load. Organic contaminants are either destroyed or converted into a gaseous state and subsequently safely treated in a multi-stage exhaust gas purification system. The process is not a combustion process but a thermal desorption procedure.
The process runs in several stages:
- Mechanical pre-treatment: The delivered sand is screened, coarse foreign materials are separated, and the material is brought to a suitable grain size and homogeneity.
- Thermal treatment in the rotary kiln: The sand passes through the rotating kiln at a defined temperature and residence time. Organic contaminants are thermally mobilized or destroyed in the process.
- Exhaust gas purification: The resulting process gases pass through dust removal, thermal post-combustion, flue gas scrubbing, and activated carbon filters before leaving the facility. This reliably ensures compliance with statutory emission limits.
- Quality control of the treated product: The treated material is analytically tested before being directed to further use or disposal.
Is blast sand suitable for thermal desorption?
Blast sand is suitable for thermal desorption when it contains organic contaminants that are volatile or destructible at the treatment temperatures. If blast sand contains exclusively heavy metal contamination without significant organic components, thermal desorption alone is insufficient, as heavy metals cannot be removed from the solid by desorption.
Blast sand from the processing of old coatings containing lead or chromium compounds frequently also contains organic components from binders, solvents, or corrosion protection resins. In these mixed contaminations, thermal treatment can reliably eliminate the organic fractions. The heavy metal fraction remains in the solid and is managed through the disposal pathway of the treated material.
The key factors for suitability are:
- Type and concentration of organic contaminants
- Proportion and binding form of heavy metals
- Grain size distribution and moisture content of the blast sand
- Results of the incoming analysis and waste characterization
Is foundry sand suitable for thermal desorption?
Foundry sand is in many cases well suited for thermal desorption, as it typically contains organic contaminants such as PAHs, phenols, and MOH, which can be reliably destroyed or driven off at temperatures of up to approximately 600 °C, depending on the material and contaminant load. The process is proven and effective for these contaminant classes.
Used foundry sand from metal processing contains different contaminants depending on the binder system used. Synthetic resin sands based on phenol or furan exhibit elevated PAH and phenol levels that are well amenable to thermal treatment. Bentonite sands contain fewer organic contaminants but may be contaminated by process residues.
Foundry sand generally has a uniform grain size and good flow properties, which favors mechanical pre-treatment and passage through the rotary kiln. A complete analysis is also required here to confirm the contaminant characteristics and determine the optimal treatment temperature.
What happens to the sand after thermal treatment?
After thermal treatment, the sand is present as a cleaned mineral substance whose contaminant levels are analytically verified. Depending on the results, the treated material can be used as a secondary raw material in earthworks or as backfill material, or directed to regulated disposal. Recycling is possible when the applicable limit values are met.
The recyclability of the treated sand depends on the limit values of the relevant regulations, in particular the Federal Soil Protection and Contaminated Sites Ordinance (BBodSchV) and the Mantelverordnung. Whether and at what quality level recycling is possible is determined by the initial contamination and the cleaning performance achieved.
Within the framework of material flow management, the destination of the treated material can be planned at an early stage to both optimize disposal costs and meet the requirements of the responsible authorities.
Which permits and documentation are required for the disposal of blast sand or foundry sand?
The disposal of contaminated blast sand or foundry sand requires complete waste characterization, correct waste code assignment in accordance with the European Waste List (EWL), and the engagement of a certified waste management company. If the waste is classified as hazardous, the documentation requirements of the Circular Economy Act (KrWG) additionally apply.
The following steps and documentation are specifically relevant:
- Waste characterization: Representative sampling and chemical analysis by an accredited laboratory to document the type and concentration of contaminants
- Waste code: Assignment of the correct EWL code, for example from Chapter 10 (wastes from thermal processes) for foundry sand or Chapter 12 (wastes from the shaping and physical and mechanical surface treatment of metals) for blast sand
- Classification as hazardous or non-hazardous waste: Decisive for the applicable documentation procedures (electronic documentation procedure for hazardous waste)
- Accompanying documents: Acceptance certificate or disposal documentation depending on waste classification
- Certified waste management company: The appointed disposal company must be certified in accordance with § 52 KrWG
Early coordination with the waste management company facilitates correct classification and avoids delays in the disposal process. For complex contamination profiles, a direct preliminary inquiry with the facility operator is recommended to clarify acceptance eligibility and the appropriate treatment pathway. Further information on quality management provides details on the underlying certifications and requirements.
ARE Deutzen as a contact partner for the disposal of blast sand and foundry sand
ARE Deutzen GmbH has more than 30 years of experience in the thermal treatment of contaminated mineral waste and offers concrete solutions for the disposal of blast sand and foundry sand with organic contaminant fractions. The facility in Deutzen is approved under the Federal Immission Control Act and certified as a waste management company in accordance with § 52 KrWG.
The range of services includes:
- Acceptance and assessment of blast sand and foundry sand based on incoming analysis
- Thermal treatment in the rotary kiln at temperatures of up to approximately 600 °C under oxygen exclusion, depending on the material and contaminant load
- Multi-stage exhaust gas purification to comply with all statutory emission limits
- Complete documentation and record-keeping in accordance with KrWG
- Consulting on waste characterization, waste code assignment, and disposal logistics
If you wish to dispose of contaminated blast sand or foundry sand safely and in compliance with regulations, please contact ARE Deutzen directly. Our team will advise you on the acceptance eligibility of your material and support you from the initial inquiry through to completed disposal.