How Is Treated Soil Sampled After Desorption?

Markus Reichenbach ·

After thermal desorption, treated soil is tested for residual contaminants through systematic sampling. Representative samples are taken from the treated material, analyzed in an accredited laboratory, and compared with the applicable limit values. Only once the soil meets the requirements is it formally cleared for recovery or disposal. The following sections explain which limit values apply, how sampling is carried out, and who grants clearance.

Which limit values apply to thermally treated soil?

In Germany, thermally treated soil is primarily governed by the precautionary and assessment values of the Federal Soil Protection and Contaminated Sites Ordinance (BBodSchV) as well as the assignment values of the Länder Working Group on Waste (LAGA). Which specific limit value applies depends on the intended use of the treated material and the requirements of the competent authority.

If the soil is to be recovered after thermal soil treatment, the LAGA assignment values for classes Z0 or Z1 are generally decisive. These define permissible contaminant levels for heavy metals, organic compounds such as PAHs, TPH, BTEX, and PCBs, as well as other relevant parameters. Stricter precautionary values apply for particularly sensitive use scenarios, such as installation in children’s playgrounds or residential gardens.

In addition, project-specific requirements may arise from the operating permit of the treatment facility or from regulatory conditions attached to the individual remediation project. These must be established as binding before sampling begins.

How is sampling carried out after thermal desorption?

Sampling of soil after desorption follows a defined sampling plan based on recognized technical standards, in particular DIN EN 14688 and the LAGA PN 98 guidelines. Representative individual samples are taken from the treated soil material and combined into a composite sample. The basis is generally a defined lot weight, typically between 500 and 1,000 tonnes.

The sampling itself is carried out systematically across the entire material stockpile or conveyor belt to ensure uniform representation. Proper storage and transport of the samples is essential to prevent contamination or loss of contaminants. All steps are documented, including the sampling location, time, and responsible person.

Which analytical methods are used in the laboratory?

In the laboratory, standardized analytical methods are used for quality testing of treated soil after desorption, varying according to the contaminant spectrum. Typical procedures include gas chromatography with mass spectrometry (GC-MS) for organic compounds such as PAHs, TPH, BTEX, and PCBs, as well as atomic absorption spectrometry (AAS) or ICP-MS for heavy metals such as mercury.

For specific contaminants such as PFAS, PCDD/PCDF, or nitroaromatics, specialized methods are employed, such as high-performance liquid chromatography (HPLC) or high-resolution mass spectrometry. Laboratory analyses must be carried out by an accredited testing laboratory in accordance with DIN EN ISO/IEC 17025 in order for the results to be officially recognized. Only in this way is a legally sound clearance of the treated material possible.

What happens if the treated soil exceeds the limit values?

If the treated soil exceeds the established limit values after desorption, it may not be cleared. The material must either be subjected to renewed thermal treatment or assigned to secured disposal, for example by landfilling at a licensed facility.

First, it is examined whether the exceedance of limit values is attributable to an insufficient treatment temperature, an excessively short residence time in the rotary kiln, or inhomogeneous feeding. On this basis, the process parameters are adjusted and the affected material lot is treated again. Within the framework of material flow management, the material is kept in secure interim storage until a compliant solution has been found. Clearance for uncontrolled recovery is not permissible under any circumstances.

Who is officially authorized to carry out sampling and clearance?

Sampling and the clearance based on it must be carried out by qualified and authorized persons. These are generally publicly appointed and sworn experts, recognized testing bodies under state law, or accredited testing laboratories acting on behalf of the facility operator or the competent authority.

The facility operator itself, i.e., the operator of the thermal treatment facility, is obliged under its self-monitoring duties to carry out and document regular quality checks. In addition, the competent licensing authority may order official third-party monitoring. Clearance of the treated material is issued in writing and requires a positive analytical result from an accredited laboratory. The quality management system of the facility operator governs internal responsibilities and clearance processes in a binding manner.

How are the results of sampling documented?

The results of soil sampling after desorption are recorded in a test report issued by the accredited laboratory. This contains the sampling data, the analytical methods applied, the measured contaminant levels, and the comparison with the applicable limit values. The report forms the basis for formal clearance and must be archived in a revision-proof manner.

In addition, a delivery note or waste disposal certificate is prepared, identifying the treated material, its weight, the treatment site, and the analytical result. These documents accompany the material upon handover to the client or transfer to a recovery facility. For the disposal of hazardous waste, the verification procedure under the Waste Verification Ordinance (NachwV) must also be observed, which requires electronic disposal certificates and accompanying documents.

Complete documentation is not only required by law but also protects all parties involved in the event of subsequent inquiries by authorities or clients.

How ARE Deutzen GmbH supports sampling and clearance of treated soils

ARE Deutzen GmbH has been operating a thermal soil treatment facility in western Saxony for over 30 years and has extensive experience in quality testing and clearance of treated mineral materials. The rotary kiln operates at temperatures of up to approximately 600 °C, depending on the material and contaminant load involved. As a certified waste management company (EfB) under the Circular Economy Act and a company certified to ISO 9001, 14001, and 50001, ARE Deutzen ensures that all sampling and documentation steps comply with statutory requirements.

The range of services in the area of quality testing specifically includes:

  • Systematic sampling in accordance with recognized standards (LAGA PN 98, DIN EN 14688)
  • Commissioning of accredited testing laboratories for all relevant contaminant parameters
  • Evaluation of analytical results in comparison with the limit values established by the authorities
  • Complete documentation including test reports, delivery notes, and disposal certificates
  • Coordination with licensing authorities in the event of non-conforming findings
  • Secure interim storage of material until clearance has been completed

If you need contaminated soil treated or have questions about sampling after desorption, contact ARE Deutzen directly. The contact persons will advise you on your specific project and support you from delivery through to documented clearance of the treated material.