What Factors Influence the Cleaning Performance in Thermal Desorption?

Markus Reichenbach ·

The cleaning performance in thermal desorption is determined by four key factors: treatment temperature, residence time in the rotary kiln, the material composition of the soil, and controlled oxygen exclusion. Those who understand and precisely control these variables consistently achieve cleaning results that meet legal requirements. The following sections answer the most important questions about the efficiency of thermal soil treatment.

Which contaminants can be particularly effectively removed by thermal desorption?

Thermal desorption is particularly well suited for volatile and semi-volatile organic contaminants that evaporate or are destroyed at elevated temperatures. These include mineral oil hydrocarbons (TPH), BTEX compounds, phenols, polycyclic aromatic hydrocarbons (PAH), polychlorinated biphenyls (PCB), cyanides, and chlorinated hydrocarbons. Mercury (Hg), PFAS/PFOS, PCDD/PCDF, and nitroaromatics can also be safely removed from mineral materials using this process.

The reason for this broad applicability lies in the operating principle: through targeted heat input, contaminants are either directly destroyed or converted into a gaseous state and subsequently treated safely in a downstream exhaust gas purification system. Particularly at sites with multiple contaminations — such as those commonly found at decommissioned gasworks, industrial brownfields, or military installations — thermal soil treatment demonstrates its strengths over biological or chemical methods.

The process is less suitable for inorganic heavy metals such as lead or arsenic, which cannot be removed by evaporation. Supplementary methods are required in these cases.

How does treatment temperature affect cleaning performance?

Treatment temperature is the single most important factor in cleaning performance for thermal desorption. The higher the temperature, the more completely contaminants are evaporated or destroyed. For most organic contaminants, the effective range lies between 250 and up to approximately 600 °C, depending on the material and contaminant profile, with low-volatility compounds such as PCDD/PCDF or PCB only being fully removed at higher temperatures.

A clear principle applies: each class of contaminant has a characteristic boiling point or decomposition temperature. Highly volatile compounds such as BTEX respond at lower temperatures, while persistent organic pollutants (POPs) such as PFAS or dioxins require significantly higher energy input. Selecting the correct treatment temperature therefore requires precise knowledge of the contaminant composition.

A temperature that is too low results in incomplete cleaning and thus in exceedances of limit values in the treated material. An unnecessarily high temperature increases energy consumption and can alter the mineral structure of the soil. Temperature control in the rotary kiln must therefore be precisely calibrated to the specific contaminant profile.

Why is residence time in the rotary kiln critical?

Residence time determines how long the contaminated material is exposed to the treatment temperature, and thereby directly influences whether contaminants are completely removed. An excessively short residence time means that contaminants in the core of soil aggregates do not fully evaporate, even if the external temperature is sufficiently high.

In the rotary kiln, residence time is controlled via the rotation speed and the inclination of the kiln. The material is continuously mixed throughout the process, ensuring uniform heat distribution. This mechanism is particularly important for inhomogeneous materials containing lumps, stones, or portions with varying moisture content.

Residence time and temperature work together: a material treated at 400 °C may require a longer residence time than a comparable material treated at a higher temperature. Optimizing both parameters is one of the central technical challenges in operating a thermal desorption plant.

What role does the material composition of the soil play?

The material composition of the soil has a significant influence on the efficiency of thermal soil remediation. The most critical factors are particle size distribution, moisture content, and organic matter content. Fine-grained, clay-rich soils with high moisture content require more energy and longer residence times than sandy, dry materials.

Prior to thermal treatment, the material therefore undergoes mechanical pre-treatment. Coarse pieces are crushed, foreign matter is separated, and the material is brought to a suitable grain size and consistency. This preparation is not an optional step but a prerequisite for uniform and effective treatment in the rotary kiln.

High moisture content has an impact on two levels: on one hand, the evaporation of water consumes energy that is then unavailable for the actual contaminant desorption. On the other hand, steam can slow heat transfer to the interior of particles. Materials with more than 25 to 30 percent water content are therefore often dried prior to thermal treatment or blended with drier materials. More information on the preparation of input materials is provided by the mechanical-physical treatment process.

How does oxygen exclusion affect the treatment process?

Oxygen exclusion is a defining characteristic of thermal desorption and fundamentally distinguishes it from incineration. Without oxygen, contaminants do not combust directly in the rotary kiln; instead, they evaporate and are only destroyed in the downstream thermal afterburner at significantly higher temperatures. This principle prevents the formation of new contaminants within the kiln itself.

A key advantage of this approach is the prevention of so-called de novo synthesis, in which new dioxins and furans can form from chlorine-containing compounds under the influence of oxygen. Controlled oxygen exclusion in the rotary kiln minimizes this risk. The contaminants are instead drawn off as raw gas and treated in a multi-stage exhaust gas purification system.

This multi-stage purification includes dedusting, thermal afterburning, flue gas scrubbing, and activated carbon filtration. Only through this interplay of controlled desorption and downstream exhaust gas treatment are statutory emission limit values reliably met. Oxygen exclusion is therefore not merely a process engineering feature but a central safety measure.

How can you tell whether thermal soil treatment was successful?

The success of thermal soil treatment is demonstrated by analytical results from the treated material. The cleaned material is tested for the relevant contaminants and compared against applicable limit values — such as the requirements of the Federal Soil Protection and Contaminated Sites Ordinance (BBodSchV) or project-specific specifications. If these limit values are met, the treatment is considered successful.

In addition to the output analysis of the cleaned soil, there are further control parameters that are continuously monitored during operation:

  • Exhaust gas emissions: Continuous measurement of emissions at the stack demonstrates the proper functioning of the exhaust gas purification system.
  • Process temperatures: Temperature records from the rotary kiln and the afterburner chamber document that the required treatment conditions were maintained.
  • Residence time logs: Throughput volumes and rotation speeds are recorded and verify correct process management.
  • Eluate analyses: For the reuse of cleaned material as a construction material, eluate tests are required to demonstrate the leaching behavior of the residual materials.

Documentation of all process parameters is not only important for internal quality assurance but is also a prerequisite for regulatory compliance reporting. Information on quality management shows how systematically these processes are monitored.

How ARE Deutzen GmbH supports thermal desorption projects

ARE Deutzen GmbH has been operating one of Germany’s most experienced thermal soil treatment facilities since 1994, supporting civil engineering companies and industrial clients in the safe treatment of contaminated mineral waste. The range of services covers the entire process from delivery to documentation:

  • Analysis and assessment of the contaminant profile prior to treatment
  • Mechanical pre-treatment to prepare the input material
  • Thermal desorption in the rotary kiln at temperatures up to approximately 600 °C, depending on the material and contaminant profile, under oxygen exclusion
  • Multi-stage exhaust gas purification to meet statutory emission limit values
  • Material flow management for soils, dredged material, construction rubble, and process residues
  • Complete documentation and regulatory compliance reporting

With more than 2.5 million tonnes of treated mineral materials and over 30 years of operational experience, ARE Deutzen has the technical expertise to reliably treat even complex contaminations. Contact us to discuss your remediation project and receive a concrete proposal.